Mastering Configuration King: A Comprehensive Tutorial on Kingview SCADA29


This comprehensive tutorial delves into the intricacies of Configuration King (often referred to as Kingview, a popular SCADA software from Wonderware), a powerful and versatile monitoring and control system. This guide is designed for users of all skill levels, from beginners taking their first steps into the world of SCADA to experienced professionals looking to refine their techniques. We will cover key aspects of the software, including project creation, tag configuration, alarm management, historical data logging, and report generation, providing practical examples and troubleshooting tips along the way.

I. Setting Up Your First Kingview Project: A Step-by-Step Guide

Before diving into the complex features, let's create a basic project to understand the fundamental workflow. Upon launching Kingview, you'll be greeted with a new project wizard. Here, you'll define essential parameters such as project name, location, and communication protocols. Understanding the communication protocol is crucial, as it dictates how Kingview interacts with your PLCs (Programmable Logic Controllers) and other field devices. Common protocols include Modbus TCP/IP, Modbus RTU, OPC UA, and others. Selecting the correct protocol is the first step towards successful data acquisition. This wizard will guide you through creating a new project database, which stores all your tag information and system configurations. Remember to choose a descriptive and easily identifiable name for your project.

II. Tag Configuration: The Heart of Your Monitoring System

Tags represent the individual data points you are monitoring and controlling. Each tag corresponds to a specific variable within your PLC or other devices. Proper tag configuration is paramount. Kingview provides flexible options for defining tag properties, including data type (integer, float, string, boolean), address, scaling factors, engineering units, and alarm limits. Accurate scaling is particularly crucial for ensuring that the displayed values accurately reflect the real-world measurements. Understanding the concept of "scaling" – converting raw data from the PLC into meaningful units (e.g., converting raw sensor readings into temperature in degrees Celsius) – is essential for accurate visualization and analysis. Careful consideration of data types prevents errors and ensures seamless data handling within the system.

III. Building Your HMI (Human-Machine Interface): Visualization and Control

The HMI is the user interface, allowing operators to monitor and control the process. Kingview offers a vast library of graphical objects to create intuitive and effective displays. These include trend charts, gauges, buttons, indicators, and various other visualization elements. Efficient HMI design is crucial for effective monitoring and control. A well-designed HMI minimizes operator errors and provides clear and concise information. Consider using color coding, alarm notifications, and clear labeling to ensure easy interpretation of data. Kingview allows for dynamic display updates, reflecting real-time changes in process variables.

IV. Alarm Management: Protecting Your System

Alarm management is a vital component of any SCADA system. Kingview allows you to define various alarm conditions based on tag values. For example, you might configure an alarm to trigger if a temperature exceeds a certain threshold. Effective alarm management involves defining alarm priorities, acknowledgment procedures, and notification methods (e.g., email, SMS). Properly configured alarms prevent costly equipment damage and ensure operator awareness of critical situations. Understanding the different alarm types (e.g., high-high, high, low, low-low) and setting appropriate thresholds is key to maintaining a well-functioning system.

V. Historical Data Logging and Reporting: Analyzing Your Data

Kingview provides robust historical data logging capabilities. This feature allows you to store historical data for analysis and reporting. Understanding the configuration options for data logging, such as logging intervals and data retention policies, is crucial for efficient storage and retrieval. Kingview also allows for the generation of various reports, providing valuable insights into process performance. Effective reporting aids in identifying trends, detecting anomalies, and making data-driven decisions for process optimization.

VI. Advanced Features and Troubleshooting

Kingview offers a range of advanced features, including scripting capabilities (using VBScript), advanced alarm handling, and integration with other systems. Understanding these features allows for greater customization and flexibility. Troubleshooting common issues, such as communication errors, tag configuration problems, and HMI display malfunctions, requires a systematic approach. Regularly checking communication status, verifying tag configurations, and reviewing system logs are essential maintenance practices. Utilizing Kingview's built-in debugging tools and documentation can significantly aid in resolving issues efficiently.

This tutorial provides a foundational understanding of Kingview SCADA. Further exploration of the software's features and functionalities will enhance your proficiency in building and managing sophisticated monitoring and control systems. Remember to consult the official Kingview documentation and online resources for detailed information and advanced techniques.