Fire Alarm System Power Supply Configuration327


Proper power supply is of critical importance to a fire alarm system. It ensures that the system is functional when needed and remains operational during a fire event when most other power sources may be unavailable. There are several factors to consider when configuring a fire alarm system's power supply to ensure that it meets the requirements of the system and the code.

Types of Power Supplies

There are several different types of power supplies used in fire alarm systems:
AC Power: AC power is the most common type of power supply for fire alarm systems. It is provided by a utility company and is typically 120 volts in the United States and 230 volts in other countries.
DC Power: DC power is provided by batteries or a rectifier. Batteries are used to provide backup power in the event of an AC power failure. Rectifiers are used to convert AC power to DC power.
Solar Power: Solar power is a renewable energy source that can be used to power fire alarm systems. Solar panels convert sunlight into electricity, which is then stored in batteries.

Power Supply Sizing

The size of the power supply is determined by the load that it will be powering. The load is the total amount of current that will be drawn by the fire alarm system components. To calculate the load, add up the current draw of each component in the system.

Once the load has been calculated, the power supply can be sized. The power supply should be able to provide at least 10% more power than the calculated load. This will ensure that the power supply has enough capacity to handle any sudden increases in load.

Power Supply Location

The power supply should be located in a secure and accessible location. It should be protected from the elements and from tampering. The power supply should also be located near the fire alarm control panel.

Power Supply Redundancy

It is recommended to have redundant power supplies for all fire alarm systems. Redundant power supplies provide backup power in the event of a failure of the primary power supply. Redundant power supplies can be either AC or DC.

Fire Alarm System Power Supply Design Considerations

In addition to the factors discussed above, there are several other design considerations that must be taken into account when configuring a fire alarm system power supply:
Electrical Code: The power supply must be designed and installed in accordance with the applicable electrical code.
NEC: In the United States, fire alarm systems must be designed and installed in accordance with the National Electrical Code (NEC). The NEC requires that fire alarm systems have a dedicated, unswitched power supply.
NFPA 72: In addition to the NEC, fire alarm systems must also be designed and installed in accordance with NFPA 72, the National Fire Alarm and Signaling Code. NFPA 72 provides specific requirements for the power supply of fire alarm systems.

Conclusion

Proper power supply is essential for the reliable operation of a fire alarm system. By following the guidelines outlined in this article, you can ensure that your fire alarm system has a reliable power supply that meets the requirements of the code and the system.